Type | Double Ended Shear Beam |
Application | Weighbridge |
Output Sensitivity(FS) | 3.0 +/- 0.003 mV/V |
Creep Error (30 minutes) | +/- 0.03% FS |
Temperature Effect on Zero | +/-0.02% FS/DegC |
Temperature Effect on Output | +/-0.01% FS/DegC |
Zero balance | +/- 1% FS |
Maximum Safe Overload | 150% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Input Resistance | 770 +/- 10 Ohms |
Output Resistance | 700 +/- 5 Ohms |
Insulation resistance at 50V DC | >= 1000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -20 to +70 Deg C |
Cable Length | 2-20 m |
Type | Double Ended Shear Beam |
Material | Stainless Steel |
Ingress Protection | IP68 |
Application | Portable Weighbridge |
Features | Low Profile |
Temperature Effect on Zero | +/-0.002 FS/DegC |
Temperature Effect on Output | +/-0.001 FS/DegC |
Zero balance | +/- 1% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Input Resistance | 700+/-5ohm |
Output Resistance | 700+/-3ohm |
Insulation resistance at 50V DC | >= 1000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -20 to +70 Deg C |
Capacity | 150 Ton |
Minimum Order Quantity | 1 Piece |
Capacity | 30000 Kg |
Material | Stainless Steel |
Ingress Protection | IP68 |
Application | Hopper Scales |
Features | Hermetically Sealed |
Creep Error (30 minutes) | +/- 0.03% FS |
Temperature Effect on Zero | +/-0.020% FS/DegC |
Temperature Effect on Output | +/-0.010% FS/DegC |
Zero balance | +/- 1% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Insulation resistance at 50V DC | >= 1000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperature Range | -20 to +70 Deg C |
Cable Length | 2-20 m |
Model | HE-7610 |
Capacity | 30 Ton |
Material | Alloy Steel |
Ingress Protection | IP68 |
Application | Weigh bridge |
Features | Hardened tool steel construction |
Output Sensitivity(FS) | 2.0 +/- 0.002 mV/V |
Combined Error | +-0.02% F.S |
Creep Error (30 minutes) | < +- 0.03 % FSO |
Temperature Effect on Zero | +-0.02% F.S |
Temperature Effect on Output | +-0.02% F.S |
Zero balance | +/- 1% FS |
Maximum Safe Overload | 150% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Input Resistance | 700 +- 10 Ohms |
Output Resistance | 700 +- 7 Ohms |
Insulation resistance at 50V DC | >= 1000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -30 to +70 Deg C |
Cable Length | 10-20 meter |
Usage/Application | Weigh Bridge |
Shape | Rectangular |
Nominal Sensitivity | 2 mV/V |
Brand | LOADPIN |
Type | Double Ended Shear Beam |
Model Number | HE 7310 |
Capacity Range | 5000kgf to 200tonf |
Repairing | Yes Any Make Load Cell We Do Repair & Service |
The 7310 is a double ended shear beam load cell which is suitable for truck, tank/ silo and hopper weighing applications. This load cell is designed to withstand the rigorous of harsh environmental conditions. The cell is compatible with the unlink suspension system. Our model is available in 5 tf to 100 tf capacities.
Standard capacities | 5,10,15,20,30,45,75,100 |
Excitation voltage | 10vdc to 15vdc |
Rated output | 3. 0 mv/v |
Input resistance | 700 - 20 ohms |
Output resistance | 770 - 7. 0 ohms |
Creep (30 minutes) | < - 0. 03% fso |
Zero balance | -1. 0% fso |
Non-repeatability | < -0. 01% fso |
Hysteresis | < -0. 02% fso |
Non-linearity | < -0. 25% fso |
Safe over load | 150% of rated capacity |
Ultimate over load | 300% of rated capacity |
Allowable side load | 50% of rated capacity |
Temperature effect on o. P. | <0. 0015% fso% oc |
Temperature effect on zero | <0. 0020% fso% oc |
Environmental protection | ip67 |
Capacity kgf. | a | b | c | d | e | f | g | h | i | j | Cable length mtrs. |
5 to 10 | 197 | 165 | 50 | 43 | 43 | 41 | 17 | 30 | 22 | 35 | 5 |
15 to 30 | 261 | 216 | 75 | 62 | 67 | 65 | 25 | 30 | 35 | 49 | 10 |
40 to 50 | 388 | 324 | 98 | 74 | 87 | 84 | 41 | 40 | 45 | 80 | 20 |
75 to 100 | 490 | 387 | 133 | 108 |